Welcome to KAIDA CENTRIFUGE

Current positionNews >> Centrifuges in use and set up Notes

Centrifuges in use and set up Notes

  The adjustment of the level of centrifuge
  .centrifuge-kaida.com">Centrifuges in operation, or moved the location, the level of centrifuges must be changed, otherwise cause a serious imbalance in the functioning of the other way round. The specific method is to install the correct one good turn, will be turned on the level of Ping-yee, repeatedly adjust the centrifuges in front of the two adjustable screw. Until the full level.
b. Turn their back on the proper use of
(1) the correct installation and removal of the other way round, removed to turn their back on the proper maintenance, polished and painted the oil in a timely manner; (2) turn their back on the right choice, high-speed operation can not turn their back on the use of low-speed, or they will turn could lead to damage The incident; (3) when there is severe corrosion to be turned to stop using; (4) due to the long-term operation will be turned rise to the material fatigue damage. There is a need to make use of recorded time, turn their back on the use of the required time period, even if no eye problems should also be stopped to avoid an accident.
c. Turn the temperature setting
   There are three temperature .centrifuge-kaida.com">centrifuges, the first being that the operators use the SET knob to set the required temperature SETTEMP, second, by the operator to use OVERTEMP turned the knob to set over-temperature protection system of temperature-controlled onwards OVERTEMP, third, to When the first operation of the actual temperature ACTUALTEMP. For the normal operation of electric, and must meet the following:
ACTUALTEMP <OVERTEMP <45
When the need to set higher than OVERTEMP centrifugal chamber at the time of the actual temperature, you can set up a good, and if necessary set OVERTEMP centrifugal chamber was lower than the actual temperature should be set in two steps, first of all will be needed Set temperature, OVERTEMP will be located in the centrifugal chamber at the time of the actual temperature and 45 , the power to open centrifuges, until temperature of the centrifugal chamber dropped to below the required temperature of OVERTEMP several times, then OVERTEMP Set up to the required temperature. When not running the other way round, the actual temperature than the other way round with SET knob to set the temperature slightly, turn their back on when it will start functioning after a rapid rise to the settings, and turn their back on the process of running the actual temperature Set the temperature will be around for a slight swing, but the other way round as a result of the large volume of quality, samples can be maintained at a constant temperature value.
   As the .centrifuge-kaida.com">centrifuge to turn their back on the use of several different, each of the other way round because of the shape and material difference, the temperature would not have the same characteristics, so use a different turn, turn their back on the set and actual temperature There will be some difference between the temperature, it is necessary to accurately control the temperature, on the need to set the proper value of temperature compensation (by the operator to use knob to set COMP), refer to specific numerical Kaida centrifuges on the recommendation list, or find their own step by step. When the ambient temperature high, and the need to set the temperature below 0 "C, in order to get a lower temperature, the need to reduce speed.

 